    The system is coming up, please wait...
    U-Boot 1.1.3 (May 16 2013 - 16:48:41)
    CPU:   AMCC PowerPC 440EPx Rev. A at 660 MHz (PLB=132, OPB=66, EBC=33 MHz)
    No Security/Kasumi support
    I2C boot EEPROM enabled
    Bootstrap Option G - Boot ROM Location I2C (Addr 0x54)
    Internal PCI arbiter enabled, PCI async ext clock used
    32 kB I-Cache 32 kB D-Cache
    Board: Spike CP
    I2C:   ready
    DRAM:  Initializing DDRSDRAM
    DQS calibration - Window detected:
    max_passing_cases = 55
    wr_dqs_shift      = 87
    dll_dqs_delay_X   = 32
    dll_dqs_delay_X window = 5 - 59
    DDR0_09=0x00011d57
    DDR0_22=0x0326770b
    DDR0_17=0x20005f00
    DDR0_18=0x20202020
    DDR0_19=0x20202020
    Zeroing SDRAM...   DONE
    DDR: 1024 MB
    POST RAM test disabled.
    Now running in RAM - U-Boot at: 3fb2b000
    trap_init : 0x0
    system inventory subsystem initialized
    FLASH: Leda CFI Flash Driver Initialized
    4 MB
    ATA interface setup: io_base=0xf8f00000, port=0x3e0, ctl=0x7ec
    PCI:
    Cannot enable the PCI clock from this CP
    A CP/PCI master already enabled. PCI Master status: 0x56
    In:    serial
    Out:   serial
    Err:   serial
    Net:
    Checking system RAM - press any key to stop test
    Checking memory address: 00100000
    System RAM test using Default POST RAM Test succeeded.
    set_bootstatus: BS_LOAD_OS, platform_idx = 8
    Type run flash_nfs to mount root filesystem over NFS
    Hit ESC to stop autoboot:  0
    Map file at LBA sector 0x113970
    ## Booting image at 00400000 ...
    Image Name:   Linux-2.6.14.2
    Image Type:   PowerPC Linux Multi-File Image (uncompressed)
    Data Size:    4290075 Bytes =  4.1 MB
    Load Address: 00000000
    Entry Point:  00000000
    Contents:
    Image 0:  3211398 Bytes =  3.1 MB
    Image 1:  1078663 Bytes =  1 MB
    ## Current stack ends at 0x3FAE9BE8 => set upper limit to 0x00C00000
    ## initrd at 0x007100D4 ... 0x0081765A (len=1078663=0x107587)
    Loading Ramdisk to 1fef8000, end 1ffff587 ... OK
    initrd_start = 1fef8000, initrd_end = 1ffff587
    ## Transferring control to Linux (at address 00000000) ...
    Installing Linux 2.6 Kernel
    Attempting to find a root file system on hda2...
    INIT: version 2.78 booting
    Bypassing firmware validation.
    INIT: Entering runlevel: 3
    Starting Fabric OS Services...
    FIPS off, RRD...
    Found 1(threshold 5) abnormal reboots within 3000 seconds window(threshold)
    sys_chip_init: class 0 max 24 Done
    ethsw_ha_enabled = 1
    uptime: 4293889596; sup_qid: 0
    .
    Fabric OS (MP_7800B_2)
    MP_7800B_2 console login:
    2019/02/15-12:29:17, [HAM-1004], 7832, CHASSIS, INFO, MP_7800B, Processor rebooted - Reset.
    Internet Systems Consortium DHCP Server 4.0.0
    Copyright 2004-2007 Internet Systems Consortium.
    All rights reserved.
    Wrote 0 class decls to leases file.
    Wrote 0 leases to leases file.
    Listening on LPF/eth2/00:05:1e:df:2c:50/backplane
    Sending on   LPF/eth2/00:05:1e:df:2c:50/backplane
    Sending on   Socket/fallback/fallback-net
    SNMP Research EMANATE/Lite Agent Version 16.2.0.9
    Copyright 1989-2006 SNMP Research, Inc.
    ki_state_set: redundant ACTIVATE for instance 1
    2019/02/15-12:29:45, [FCR-1069], 7833, FID 128, INFO, MP_7800B_2, The FC Routing service is enabled.
    2019/02/15-12:29:46, [FCR-1068], 7834, FID 128, INFO, MP_7800B_2, The FC Routing service is disabled.
    2019/02/15-12:29:46, [ZONE-1022], 7835, FID 128, INFO, MP_7800B_2, The effective configuration has changed to DR_Sunguard_sw2. .
    Feb 15 12:29:49  All service instances on Active
    Board_Version=3
    Board_Version=3
    Open heartbeat: 200
    Open heartbeat: 400
    Feb 15 12:30:34  Heartbeat to 200 Up!
    POST1: Started running Fri Feb 15 12:31:03 GMT 2019
    POST1: Test #1 - Running turboramtest
    POST1: Script PASSED with exit status of 0 Fri Feb 15 12:31:07 GMT 2019 took (0:0:3)
    POST2: Started running Fri Feb 15 12:31:09 GMT 2019
    POST2: Test #1 - Running portloopbacktest (SERDES)
    POST2: Test #2 - Running fcippathtest
    MP_7800B_2 login: 2019/02/15-12:32:34, [BL-1000], 7838, CHASSIS, INFO, MP_7800B, Initializing ports...
    2019/02/15-12:32:34, [XTUN-2006], 7839, CHASSIS, INFO, MP_7800B, FCIP Tunnel 16 CREATED (API).
    2019/02/15-12:32:34, [XTUN-2007], 7840, CHASSIS, INFO, MP_7800B, FCIP Tunnel 16 Circuit 0 CREATED (API).
    2019/02/15-12:32:35, [XTUN-2006], 7841, CHASSIS, INFO, MP_7800B, FCIP Tunnel 18 CREATED (API).
    2019/02/15-12:32:35, [XTUN-2007], 7842, CHASSIS, INFO, MP_7800B, FCIP Tunnel 18 Circuit 0 CREATED (API).
    2019/02/15-12:32:35, [BL-1001], 7843, CHASSIS, INFO, MP_7800B, Port initialization completed.
    MP_7800B_2 console login: user
    Password:
    MP_7800B_2:user> licenseshow
    : Enhanced Group Management license
    : 7800 Upgrade license
    MP_7800B_2:user> version
    Kernel:     2.6.14.2
    Fabric OS:  v7.1.1
    Made on:    Wed May 29 22:35:10 2013
    Flash:      Sat Nov 2 16:27:55 2013
    BootProm:   1.0.10
    MP_7800B_2:user> switchshow
    switchName:     MP_7800B_2
    switchType:     83.3
    switchState:    Online
    switchMode:     Native
    switchRole:     Principal
    switchDomain:   2
    switchId:       fffc02
    switchWwn:      10:00:00:05:1e:df:2c:4f
    zoning:         ON (DR_Sunguard_sw2)
    switchBeacon:   OFF
    FC Router:      OFF
    FC Router BB Fabric ID: 1
    Address Mode:   0
    Index Port Address Media Speed       State   Proto
    ==================================================
    0   0   020000   id    N8       No_Light    FC
    1   1   020100   id    N8       No_Light    FC
    2   2   020200   id    N8       No_Light    FC
    3   3   020300   id    N8       No_Light    FC
    4   4   020400   id    N8       No_Light    FC
    5   5   020500   id    N8       No_Light    FC
    6   6   020600   id    N8       No_Light    FC
    7   7   020700   id    N8       No_Light    FC  Disabled (Persistent)
    8   8   020800   id    N8       No_Light    FC  Disabled (Persistent)
    9   9   020900   id    N8       No_Light    FC  Disabled (Persistent)
    10  10   020a00   id    N8       No_Light    FC  Disabled (Persistent)
    11  11   020b00   id    N8       No_Light    FC  Disabled (Persistent)
    12  12   020c00   id    N8       No_Light    FC  Disabled (Persistent)
    13  13   020d00   id    N8       No_Sync     FC  Disabled (Persistent)
    14  14   020e00   id    N8       No_Light    FC  Disabled (Persistent)
    15  15   020f00   id    N8       No_Light    FC  Disabled (Persistent)
    16  16   021000   --    --       Offline     VE
    17  17   021100   --    --       Offline     VE
    18  18   021200   --    --       Offline     VE
    19  19   021300   --    --       Offline     VE
    20  20   021400   --    --       Offline     VE
    21  21   021500   --    --       Offline     VE
    22  22   021600   --    --       Offline     VE
    23  23   021700   --    --       Offline     VE
    ge0           cu    1G       No_Sync   FCIP  Copper
    ge1           cu    1G       No_Sync   FCIP  Copper
    ge2           --    1G       No_Module FCIP
    ge3           --    1G       No_Module FCIP
    ge4           --    1G       No_Module FCIP
    ge5           --    1G       No_Module FCIP
    MP_7800B_2:user> chassisshow
    Chassis Backplane Revision: 0
    FAN  Unit: 1
    Time Awake:             0 days
    FAN  Unit: 2
    Time Awake:             0 days
    POWER SUPPLY  Unit: 1
    Time Awake:             0 days
    POWER SUPPLY  Unit: 2
    Time Awake:             0 days
    CHASSIS/WWN  Unit: 1
    Header Version:         2
    Factory Part Num:       40-1000246-19
    Factory Serial Num:     ASS0609F00M
    Manufacture:            Day:  1  Month:  2  Year: 2010
    Update:                 Day:  1  Month:  7  Year: 2018
    Time Alive:             2877 days
    Time Awake:             0 days
    ID:                     EMC0000CA
    Part Num:               CONTRX0000780
    Serial Num:             BRCASS0609F00M
    MP_7800B_2:user> firmwareshow
    Appl     Primary/Secondary Versions
    ------------------------------------------
    FOS      v7.1.1
    v7.1.1