DC DC Buck Boost Converter AdjustableDescription:
ZK-4KX is a DC-DC adjustable constant voltage constant current automatic buck-boost power supply module with LCD display. HD display input voltage and output voltage, current, power, display status, capacity, energy and time. Adjustable stable output voltage and current. Set output current to meet the require. It can be used as ordinary buck power supply module, charger and LED constant current driver. Simple and efficient, practical.
It supports solar charging and can be connected to solar battery.
Features:
1>.High quality heat sink
2>.Multiple parameters are displayed simultaneous
3>.Enabled/disabled output
4>.Automatic buck/boost voltage
5>.Constant voltage constant current output
6>.Solar charging
7>.Input anti-reverse protection
8>.Output anti-backflow protection
9>.Under voltage protection
10>.Over-voltage protection
11>.Over-current protection
12>.Over power protection
13>.Over temperature protection
14>.Timeout protection
15>.Over capacity protection
16>.Display input voltage
17>.Display output voltage, current, power
18>.Working status indicator
Parameters:
1>.Product Name:ZK-4KX DC-DC Step UP Down Power Supply Module
2>.Product Number:ZK-4KX
3>.Working Voltage: DC 5V-30V
4>.Output Voltage: DC 0.5V-30V
5>.Output Power:50W(Max and need fan. Default 35W)
6>.Output Current:4A(Max)
7>.Voltage Display Resolution:0.01V
8>.Voltage Display Resolution:0.001A
9>.Conversion efficiency: About 88%
10>.Work frequency:180KHz
11>.Working Temperature range:-20℃~100℃
12>.Working Humidity range:0%-95%RH
13>.Size:79*43*49mm
Normal Display Mode:
1>.Default normal display.
2>.Long press means need keep press for more than 2second.
3>.Short press SW button to switch display output current A, output power W, output capacity Ah, output time h at the second line.
4>.Long press SW button to switch display input voltage, output voltage, temperature at the first line.
5>.Short press U/I button enter into CVCC Mode to adjust output voltage and output current.
6>.Long press U/I button enter into Parameter Set Mode.
7>.Short press potentiometer to turn ON/OFF output.
8>.Rotary potentiometer to adjust output voltage.
Parameter Set Mode:
1>.Short press SW button to select the parameters which need to set. It can set Default Output Status OPEN, LVP, OVP, OCP, OPP, OAP, OHP, OTP, IN CAL V, OUT CAL V, OUT CAL V.
2>.Long press U/I button to save parameter value and exit Parameter Set Mode and return to Normal Display Mode.
3>.Short press potentiometer to select set bit at selected parameter value.
4>.Long press potentiometer to turn ON/OFF parameter function if need.
5>.Rotary potentiometer to adjust parameter value.
6>.Output Status OPEN. It is used to set output status when power ON.
7>.LVP. It is used to set input under voltage protection value.
8>.OVP. It is used to set output over voltage protection value.
9>.OCP. It is used to set output over current protection value.
10>.OPP. It is used to set output over power protection value. This function can be disabled.
11>.OAP. It is used to set maximum output capacity value. This function can be disabled.
12>.OHP. It is used to set maximum work time.
13>.OTP. It is used to set maximum work temperature value.
14>.IN CAL V:It is used to calibrate the input voltage value. Note: Only valid for voltages more than 12V.
15>.OUT CAL V:It is used to calibrate the output voltage value. Note: Only valid for voltages more than 12V.
16>.OUT CAL A:It is used to calibrate the output current value. Note: Only valid for current more than 1A.
CVCC Mode:
1>.CVCC Mode is used to adjust output voltage and output current.
2>.Short press U/I button to switch select output voltage, output current and exit.
3>.Short press potentiometer to select set bit at selected parameter value.
4>.Rotary potentiometer to adjust parameter value.
Auxiliary Function:
1>.Statistics Capacity and work time: The statistics are started when turn ON output, and the statistics are stopped when the turn ON at next time.
2>.Set Maximum Output Capacity OAH:ZK-4KX disabled output and LCD flashing display OAH when Statistics Capacity Value is more than set maximum value OAH if enabled OAH function. Automatically clear capacity statistics after the alarm is cleared. ZK-4KX will automatically count whether or not OAH is enabled. But output will not disabled output if disabled OAH function.
4>.Set Maximum Running Time OHP:ZK-4KX disabled output and LCD flashing display OHP when Statistics Work Time is more than set maximum value OHP if enabled OHP function. Automatically clear work time statistics after the alarm is cleared. ZK-4KX will automatically count whether or not OHP is enabled. But output will not disabled output if disabled OHP function. It is countdown mode if enabled OHP.
5>.CC display: CC indicator will turn ON if output current reaches the set current value.
Protection mechanism:
1>.ZK-4KX supports reverse protection at input terminal.
2>.ZK-4KX supports anti-backflow protection at output terminal.
3>.LVP Under voltage protection. The default protection value is 4.8V and set range is DC 4.8V~30V adjustable. Screen will display OVP and flashing after start over voltage protection. In the battery discharge test, setting the appropriate LVP can effectively prevent the battery from being over-discharged, so as not to damage the battery.
3>.OVP over voltage protection. The default protection value is 31V and set range is DC 0.5V~31V adjustable. But user can modify the values as required. Screen will display OVP and flashing after start over voltage protection.
4>.OCP over current protection. The default protection value is 4.10A and set range is 0A~4.1V adjustable. But user can modify the values as required. Screen will display OCP and flashing after start over current protection.
5>.OPP over power protection. The default protection value is 35W and set range is 0W~50W adjustable. But user can modify the values as required. Screen will display OPP and flashing after start over power protection.
6>.OAP over capacity protection. The default protection function is disabled. But user can modify the values as required and user can turn ON and set range is 0Ah~60Ah.Screen will display OAP and flashing after start over capacity protection.
7>.OHP timeout protection. The default protection function is disabled. But user can modify the values as required and user can turn ON and set range is 00:00h~99:59h.Screen will display OAP and flashing after start over capacity protection.
8>.OTP over temperature protection. The default protection value is 110℃ and set range is 80℃~110℃ adjustable. Screen will display OTP and flashing after start over temperature protection.
Using Steps:
1>.As a ordinary step up/down power module:
1.1>.Connect right input voltage at input terminal;
1.2>.Rotary potentiometer to set output voltage according to require. LCD display CV symbol.
1.3>.Keep press potentiometer 1second to adjust output constant current value. Then rotary potentiometer to set value. LCD display CC and SET symbol.
1.4>.Test and using(Module’s maximum output current is 2A if display 2A on multimeter. LCD will display symbol CC if output reach to 2A.Otherwise display CV.)
1.5>.The output voltage will decrease due to the current sampling resistor at the output. The higher the current, the more the voltage is reduced.
2>.As a charger:
2.1>.Tops: Power module can not be used as charger module if it does not support constant current function. The voltage difference between the battery with insufficient voltage and the charger is very large. Causes excessive charging current even damage the battery. So it need keep charging in constant current mode to reaching a certain level. Then automatically switch back to constant voltage charging.
2.2>.Make sure floating charge voltage and charge current for battery. If the lithium battery’s parameter is 3.7V/2200mAh, then the float charge voltage is 4.2V, and the maximum charging current is 1C, which is 2200mA.
2.3>.Connect right input voltage at input terminal.(Note: Please don’t connect load during set parameter).
2.4>.Rotary potentiometer to set output voltage according to require. LCD display CV symbol.
2.5>.Keep press potentiometer 1second to adjust output constant current value. Then rotary potentiometer to set value. LCD display CC and SET symbol.
2.6>.Connect battery at output terminal and start to charging.
3>.As a high power LED constant current driver:
3.1>.Make sure LED working current and maximum working voltage.
3.2>.Connect right input voltage at input terminal.(Note: Please don’t connect load during set parameter).
3.3>.Rotary potentiometer to set output voltage according to require. LCD display CV symbol.
3.4>.Keep press potentiometer 1second to adjust output constant current value. Then rotary potentiometer to set value. LCD display CC and SET symbol.
3.4>.Connect LED and test.
Note:
1>.It needs to add extra cooling equipment if output current is more than 3A or output power is more than 35W.
2>.It is a DC power module, So it can not connect to AC power.
3>.Please connect input before connect battery when use as charge and make sure output voltage is higher than battery voltage.
4>.’VIN-’ and ‘OUT-’ can not be connect together. Otherwise module can not support constant current output.
5>.Keep input more than 8V is need if need ZK-4KX output in maximum power. It just can output about 15W when input 5V.
6>.Please make sure input power is more than load power.
7>.Please step down output power if module is hot.
8>.Please read use manual and description before use.
Application:
1>.Ordinary power supply;
2>.Battery charger;
3>.LED drive power;
4>.Instrument voltage display;
5>.Test meter;
6>.Circuit test;
7>.Power conversion.
Package Includes:
1 x DC DC Buck Boost Converter Adjustable.